⬡PhaseSpace

Open-source production engineering

Checked against 150 real wells.
2.9% median error.

That is the number worth leading with, because it is measured against measurement rather than against our own equations. Most of what simulation software reports about itself is the second kind. Below is the whole evidence table, including the parts we have not validated and what it would take to.

What the optimiser does with a fixed gas supply

not validated

Six wells, 2,500 mcf/d of lift gas, not a cubic foot more — solved in 10.8 ms. A real run on this engine, and an example rather than evidence: no open lift-test data exists to check an allocation against, and the engine labels its own answer a heuristic because the minimum-stable-injection limits make the first increment a jump.

WellInjectingShould beOil
W-03400250-18.7
W-07200500+35.9
W-11750500-15.5
W-12300250-5.8
W-185005000.0
W-21350500+14.3
Field1133.61143.7+10.1

Injection in mcf/d, oil in stb/d. Two wells give gas up so four can use it better.

What it is worth

$258,000 / year

At $70/bbl, from gas you are already compressing. The next mcf/d is worth $5.30 — below that, buy more; above it, stop.

The engine’s own caveat

Some wells have a minimum stable injection, so the first increment is a discrete jump rather than a marginal step. The allocation is a strong heuristic here, not a proof of optimality.

1,122
automated tests passing
150
measured surveys validated against
< 1s
typical field solve
0
rows stored

What is proved, and what is not

Verification means the code solves its own equations correctly. Validation means those equations match a real field. They are different claims and most software reports the first as though it were the second. There is no API or ISO standard for simulation validation in this industry, so we use ASME V&V 20 language and say which we have.

Tubing pressure traversevalidated2.9% median absolute bottomhole error on 150 measured gradient surveys; 101 of 150 within 5%
Hydrate formationvalidated7 of 7 real events flagged, 1 false alarm in 537 normal instances, across 12.7M observations from 23 wells. Detects concurrently — it is not early warning
Solvers against closed formsverifiedWeymouth exact to 1e-12, loop mass balance 5e-9, transient steady limit 0.59%, surge 1.045× the Joukowsky bound
Choke pressure vs a well testanecdotewithin 4.2% — one well, so it is an anecdote and not a validation
Pipeline arrival pressureanecdotewithin 5% of a field study — one study
Nodal analysis — the intersectionnot validatedthe traverse is validated; predicting the rate where IPR meets VLP is not. Needs a well with inflow and outflow measured together
Gas network hydraulicsnot validatedno public source pairs a topology with measured node pressures. Would need an operator's SCADA
Gas-lift optimisationnot validatedno open lift-test data exists. The worked example below is a heuristic, not a proof of optimality
Rod pump / Gibbsnot validatedno open labelled dynamometer card set exists anywhere. Verified against API 11L only

The full table, with what each unvalidated row would take to close, is in validation/README.md. If a vendor cannot show you theirs, that is the answer to the question.

Start from what is wrong

Not from which module you think you need. The correlation names are all still there, one level in.

The solvers against answers known independently

Closed forms, conservation laws and analytic bounds — things whose value is known without reference to this code. Published correlations, no fitted black boxes, and every result names the correlation behind it and flags when an input is outside the range that correlation was fitted on. This is verification; the table above says where it becomes validation.

Single pipe vs closed-form Weymouthexact to 1e-12
Loop network mass balance5e-9 relative
Transient limit vs the steady-state solver0.59%
Surge vs the analytic Joukowsky bound1.045× / 0.957×
Hydrate curve vs its published nomogramwithin 2%

Runs air-gapped

numpy and the standard library. No call home, no cloud dependency.

Priced per well

not per seat. The bill follows the barrels, not the headcount.

Stateless by default

the hosted solvers keep nothing. Inputs are solved and discarded.

Then come back and check it delivered.

Every optimiser will tell you a change is worth ten barrels a day. This one subtracts the well’s own decline, separates a real gain from a well that was simply up more days, and refuses to score a window another change also touched.